FREY_TONOMETER_VERT.jpg

Frey TN-100

Frey Non-contact Tonometer TN-100 is a modern diagnostic device, featuring fast, accurate examinations ensuring optimal levels of patient comfort undergoing noninvasive measurement of intraocular pressure.

TN-100 measurement is fully automated, saving time for user and patient.

Patient data storage capability and measurement values for 4000 patient data base included. Patient examination record and database is available immediately upon completion of examination.

Individual patient examination or entire patient history can printed with simple one touch. Internal printer simplifies record keeping.

KEELER_TONO_VERT.jpg

Keeler KAT / KAT-R

The KAT R-type style applanation tonometer is designed to be used with the H series slit lamp (tower illumination). The R-type tonometer is fixed allowing for it to easily swing into and out of position as needed without being removed. 

Each of these applanation tonometer units contains a calibration arm and a re-usable tonometer cone.

The Goldmann principle is considered to be the most prevalent method of tonometry, as it is the most widely accepted method of determining the approximate intraocular pressure.

The Keeler-manufactured Goldmann tonometers are designed and built to our exacting standards to give you the accuracy and quality you expect from a Keeler device. 

huvitz3x2.png

Huvitz HNT-1

Soft & Smart Puffing, Corneal Thickness Compensation, Combined with Great Economical Value

A New Standard in Intraocular Pressure Measurement.

The new tonometer HNT-1/1P measures customized intraocular pressure with smart function auto-adjustable puffing intensity. Intuitive interface based on corneal thickness to compensate for IOP value, produces accurate measuring data immediately and effortlessly.

accupen.png

Accutome Accupen

Gravity Offset Technology provides precise IOP measurements with less calibration compared to other handheld tonometers. Micro strain gauge technology combined with proprietary algorithms provide reproducible results.

  • Ergonomic design combined with sighting lines allow for easy visualization of the cornea, facilitating both centralization and perpendicularity.

  • Contoured molding with a large, visable LCD allows the AccuPen to be used ambidextrously and fit comfortably in any size hand.

  • Eliminates the constant need for "up, down and around" calibration.

  • Long lasting lithium battery lasts up to 15,000 readings.

  • Weighs only 3.0oz and comes with custom, heavy duty traveling case and lanyard for safe transportation.

  • Takes fast measurements with patient in any position. Frees up valuable office space.

  • Stores and averages nine measurements. Built in IOP Correction Calculator adjusts IOP based on central corneal thickness.

Tonocare

Keeler Tonocare

The TonoCare is set to revolutionise the hand-held market. Designed and built with patient comfort in mind, the TonoCare is
truly simple to use and gives consistently fast, accurate and reliable readings. Whatever the mobility of the patient and wherever it’s being used, the TonoCare offers exceptional performance time and time again.